void-packages/srcpkgs/upower/patches/upower-0.99.0-fix-segfault.patch
2015-03-04 15:48:55 +01:00

24 lines
829 B
Diff

From 0d64bbddaa0078ef148d609a3cfad854cf00d7de Mon Sep 17 00:00:00 2001
From: Martin Pitt <martinpitt@gnome.org>
Date: Fri, 08 Nov 2013 13:59:50 +0000
Subject: lib: Fix segfault on getting property when daemon is not running
This fixes "upower --version" when the daemon is not running, and thus the
client proxy is NULL.
---
diff --git a/libupower-glib/up-client.c b/libupower-glib/up-client.c
index 35d7b5d..17fb02d 100644
--- a/libupower-glib/up-client.c
+++ b/libupower-glib/up-client.c
@@ -322,6 +322,9 @@ up_client_get_property (GObject *object,
UpClient *client;
client = UP_CLIENT (object);
+ if (client->priv->proxy == NULL)
+ return;
+
switch (prop_id) {
case PROP_DAEMON_VERSION:
g_value_set_string (value, up_client_glue_get_daemon_version (client->priv->proxy));
--
cgit v0.9.0.2-2-gbebe